Error -205177: Failed to startup RRE due to a timeoutfunction xlrCReplayEngineStartupNotifier::WaitForStartupNotification
Problem
During the replay of an Ajax TruClient script in Vugen or the Controller the following error was observed:
Error -205177: Failed to startup RRE due to a timeoutfunction xlrCReplayEngineStartupNotifier::WaitForStartupNotification in .\xlrReplayEngineStartupNotifier.cpp(82), modified Sun Sep 5 16:57:31 2010, compiled Sep 14 2010 08:22:14 [MsgId: MERR-205177]
Error -205177: Internal Error – Failed on Wait for Startup [MsgId: MERR-205177]
Cause
The script was saved in a UNC path location (network drive) and is missing files from the RRE folder where the script is saved.
Solution
Two workarounds are available to resolve this issue as follows:
Option A:
First save the script locally and then save it in the UNC path.
Option B:
- Save the script in the UNC path
- Open the script directory
- Rename the RRE folder
- Reopen the script