Error: Fail happened at Sprinter, and execution of tests from within QC will not be enabled

The reason for the problem is conflict between the Sprinter communication port and ALM JBoss connection port 8080.

The problem is fixed with one of below solutions:

Change the JBoss connection port from 8080 to another, for example 8081 – please check the installation guide for HP ALM.

Running below command in command prompt:

netsh http add iplisten ipaddress=<IP Address of your computer>:8080 (e.g.: netsh http add iplisten ipaddress=16.17.30.40:8080)

Required restart of the machine.