Does Sprinter 11.0 support testing Siebel applications

Sprinter 11.0 does not have special support for testing Siebel applications. It is recommended to use QuickTest Professional(QTP) for testing Siebel applications.

URL attachments to Sprinter test steps are always opened with Google Chrome

When Google Chrome is installed on the Sprinter system, URL attachments to Sprinter test steps are opened through Chrome browser even if the system default browser is Internet Explorer or FireFox and .url file extension is associated to one of them.

This is a defect in Sprinter, it takes the browser path from a path set in the Windows registry key (Computer\HKEY_CLASSES_ROOT\http\shell\open\command).

This will be solved in future Sprinter releases. As a workaround until then, please perform the below steps to modify Sprinter behavior when opening URL attachments:

1. Open Windows registry by selecting “Start > Run” and typing regedit.

2. Navigate to the registry key: Computer\HKEY_CLASSES_ROOT\http\shell\open\command

3. Edit the string value contained in the key as: “<path_to_iexplore.exe>” –nohome

4. Restart the machine to allow the changes to take effect.

“Invalid Command Line…” error when trying to launch Sprinter Results Viewer from ALM/QC intertface with user which ALM/QC user name contains spaces

"Invalid Command Line…received at Sprinter Viewer"

It seems that the command line is not parsed properly and the user name is split after each space character.

Open the results directly in Sprinter from ‘Test Lab -> Execution Grid -> Continue with Sprinter’ or from ‘Test Instance Details -> Runs -> Continue with Sprinter’.