Modify the local data table for a reusable action

Select the "Use a local editable copy" option

QuickTest Professional 8.x and above
1. Insert the call to the action.
2. In the Keyword View, right-click on the action and select "Action Properties".
3. Select the External Action tab.
4. Select the "Use a local, editable copy" radio button.
5. Click <OK>.

Unified Functional Testing 11.5x and above
1. Insert the call to the action.
2. In the Test Flow view, right-click on the action and select "Action Properties".
3. Select the External Action tab.
4. Select the "Use a local, editable copy" radio button.
5. Click <OK>.

QuickTest Professional 6.5
When inserting a call to an Action, select the "Use a local editable copy" radio button under the "Parameter Data" section.