Inactivity timer throws negative minutes in message

When the inactivity timer sends a message, the onscreen message is ok but the popup message looks like:

Your inactive HP Service Manager session (UID# 5) will be automatically disconnected in -2132464512 minute(s) 270643684 second(s)

One scmessage record seems to be wrong in the database. This could be caused by migration from earlier SM versions.

Wrong scmessage record :

Class=scbase

Message number=130

Text: Your inactive HP Service Manager session (UID# %ld) will be automatically disconnected in %d minute(s) %d second(s)

To fix this issue overwrite the Text in scmessage record

Your inactive HP Service Manager session (UID# %ld) will be automatically disconnected in %d minute(s) %d second(s)
with
Your inactive session will terminate in %ld minutes,do you want to extend your session time?

How to modify the scmessage record:

1. Command db

2. Table: scmessage

3. Search

4. Search for this scmessage record with class “scbase” and message number “130”.

5. Correct the Text

6. Save the record

Advertisements